Sample gas probe RSP-1

Sample gas probe RSP-1
RSP-1HB / RSP-1HX / RSP-1XX

Sample gas probes extract sample gas unadulterated from processes and make it available for further analysis. Unwanted contaminants are already filtered at the sampling point. The maintenance of the probes is easy and possible without great use of special tools.

Information about sample gas probes for potentially explosive areas.

https://robecco.net/en/analysis-technology-components/sample-gas-probe-rsp-1-ex/

Sample gas probe RSP-1HB

Heated probe with Inlet/Outletfilter and weather protective hood, blow back
Fast changing of filter elements
Low-maintenance
Large active filter surface
For dust concentrations up to 2g/m3 with Outletfilter
for dust concentr. up to 10g/m3 with Prefilter
für Staubbelastung bis zu 10g/m3 mit Vorfilter
With blow back
Heated, 80°C

Technical data

Material
Stainless steel 1.4301
Gas contacting materials: 1.4404
Sealing: Klingensil C4400
Filter element: Sintered metal 316L, 1.4404
Operating pressure
max. 200kPa abs.
Inlet temp. process medium
max. 200°C
Ambient temperature
-20 °C bis +60°C
self limiting heater
ca. 80°C
power consumption heater
110 – 265 VAC, 50/60 Hz, 50 Watt
power consumption valve
24 VDC, 9 Watt
Sample gas input
G3/4″ female thread
Sample gas outlet
4/6 tube connection
Compressed air connection
12 mm outside diameter
P max Compressed air
10 bar
Filter element (Outlet filter)
Process connection
DN 65 / PN 6
Dimensions
L 470 mm / W 345 mm / H 260 mm
Weight
ca.12 kg

Sample gas probe RSP-1HX

Heated probe with Inlet/Outletfilter and weather protective hood, blow back
Fast changing of filter elements
Low-maintenance
Large active filter surface
For dust concentrations up to 2g/m3 with Outletfilter
for dust concentr. up to 10g/m3 with Prefilter
für Staubbelastung bis zu 10g/m3 mit Vorfilter
With blow back
Heated, 80°C

Technical data

Material
Stainless steel 1.4301
Gas contacting materials: 1.4404
Sealing: Klingensil C4400
Filter element: Sintered metal 316L, 1.4404
Operating pressure
max. 200kPa abs.
Inlet temp. process medium
max. 200°C
Ambient temperature
-20 °C bis +60°C
self limiting heater
ca. 80°C
power consumption heater
110 – 265 VAC, 50/60 Hz, 50 Watt

Sample gas input
G3/4″ female thread
Sample gas outlet
4/6 tube connection


Filter element (Outlet filter)
Process connection
DN 65 / PN 6
Dimensions
L 390 mm / W 215 mm / H 260 mm
Weight
ca.9 kg

Sample gas probe RSP-1XX

Heated probe with Inlet/Outletfilter and weather protective hood, blow back
Fast changing of filter elements
Low-maintenance
Large active filter surface
For dust concentrations up to 2g/m3 with Outletfilter
for dust concentr. up to 10g/m3 with Prefilter
für Staubbelastung bis zu 10g/m3 mit Vorfilter
With blow back
Heated, 80°C

Technical data

Material
Stainless steel 1.4301
Gas contacting materials: 1.4404
Sealing: Klingensil C4400
Filter element: Sintered metal 316L, 1.4404
Operating pressure
max. 200kPa abs.
Inlet temp. process medium
max. 250°C
Ambient temperature
-20 °C bis +60°C


– 

– 
Sample gas input
G3/4″ female thread
Sample gas outlet
4/6 tube connection


Filter element (Outlet filter)
Process connection
DN 65 / PN 6
Dimensions
L 255 mm / W 215 mm / H 260 mm
Weight
ca.9 kg

Options: Extension sampling tubes, calibration gas connection 6mm, prefilter

Order numbers

Sample gas probe RSP-1HB (with blowback)R000825
Sample gas probe RSP-1HXR000826
Sample gas probe RSP-1XX (without heating/ without. blowback.)R000827
Flange DN 65/PN6R000335
Extension sampling tube E 500R000172
Extension sampling tube E 1000R000039
Prefilter F 200 5μR000792
Spare part kit for RSP-1HB-EX, RSP-1HX-EX & RSP-1XX
consisting of 1x filter element 3μ, 1x Seal for
filter element, 1x Flat seal probe body
R001886

Conditions | AEB | Imprint Data ProtectionDownloadarea