Sample gas probe RSP-1 EX

Explosionsschutzkennzeichen für Geräte und SchutzsystemeSample gas probe RSP-1 EX
RSP-1HB-EX / RSP-1HX-EX / RSP-1XX

Sample gas probes extract sample gas unadulterated from processes and make it available for further analysis. Unwanted contaminants are already altered at the sampling point. The maintenance of the probes is easy and possible without great use of specials tools.

Sample gas probe RSP-1HB-EX

Heated probe with Inlet/Outletfilter and weather protective hood, blow back
Fast changing of filter elements
Low-maintenance
Large active filter surface
For dust concenter. up to 2g/m3 with Outletfilter
for dust concenter. up to 10g/m3 with Prefilter
Without blow back
heated, 80°C
Installation in EX-zone 21, 22

Technical data

Material
Stainless steel 1.4301
Gas contacting materials: 1.4404
Sealing: Klingensil C4400
Filter element: Sintered metall316L, 1.4404
Operating pressure
max. 200kPa abs.
Inlet temp. process medium
max. 135°C
Ambient temperature
-20 °C to +60°C
self limiting heater
ca. 80°C
power consumption heater
110 – 265 VAC, 50/60 Hz, 50 Watt
power consumption valve
24 VDC, 9 Watt
Sample gas input
G3/4″ female thread
Sample gas outlet
4/6 tube connection
Compressed air connection
12 mm outside diameter
P max compressed air
10 bar
Filter element (Outlet filter)
Process connection
DN 65 / PN 6
Dimensions
L 470 mm / W 345 mm / H 260 mm
Weight
ca.12 kg

Sample gas probe RSP-1HX-EX

Heated probe with Inlet/Outletfilter and weather protective hood, blow back
Fast changing of filter elements
Low-maintenance
Large active filter surface
For dust concenter. up to 2g/m3 with Outletfilter
for dust concenter. up to 10g/m3 with Prefilter
Without blow back
heated, 80°C
Installation in EX-zone 21, 22

Technical data

Material
Stainless steel 1.4301
Gas contacting materials: 1.4404
Sealing: Klingensil C4400
Filter element: Sintered metall316L, 1.4404
Operating pressure
max. 200kPa abs.
Inlet temp. process medium
max. 135°C
Ambient temperature
-20 °C to +60°C
self limiting heater
ca. 80°C
power consumption heater
110 – 265 VAC, 50/60 Hz, 50 Watt
 
 
Sample gas input
G3/4″ female thread
Sample gas outlet
4/6 tube connection
 
 
P max Druckluft
10 bar
Filter element (Outlet filter)
Process connection
DN 65 / PN 6
Dimensions
L 390 mm / W 215 mm / H 260 mm
Weight
ca. 9 kg

Sample gas probe RSP-1XX

Heated probe with Inlet/Outletfilter and weather protective hood, blow back
Fast changing of filter elements
Low-maintenance
Large active filter surface
For dust concenter. up to 2g/m3 with Outletfilter
for dust concenter. up to 10g/m3 with Prefilter
Without blow back
unheated
Installation in EX-zone 21, 22

Technical data

Material
Stainless steel 1.4301
Gas contacting materials: 1.4404
Sealing: Klingensil C4400
Filter element: Sintered metall316L, 1.4404
Operating pressure
max. 200kPa abs.
Inlet temp. process medium
max. 135°C
Ambient temperature
-20 °C to +60°C
 
 
 
 
 
 
Sample gas input
G3/4″ female thread
Sample gas outlet
4/6 tube connection
 
 
P max Druckluft
10 bar
Filter element (Outlet filter)
Process connection
DN 65 / PN 6
Dimensions
L 255 mm / W 215 mm / H 260 mm
Weight
ca.9 kg

Options: Extension sampling tubes, calibration gas connection 6mm, prefilter

Order numbers

Sample gas probe RSP-1HB -EX (with blow back+heating)R000823
Sample gas probe RSP-1HX-EX (with heating)R000824
Sample gas probe RSP-1XX (without heating/ without blow back)R000827
Flange sealing DN 65/PN6R000335
Extension sample tube E 500R000172
Extension sampling tube E 1000R000039
Prefilter F 200 5μR000792
Spare part for RSP-1HB-EX, RSP-1HX-EX & RSP-1XX
consisting of 1x filter element 3μ, 1x Sealing for
filter element, 1x at seal probe body
R001886