Flow meter SM-M | SM-VA | SM-K
Flow meter for direct reading of the current flow of gases. The flow of the media lifts a floating cone. This indicates the flow on a scale.
DOWNLOAD Specification sheet: robecco Strömungsmesser | Flow meter
Flow meter for direct reading of the current flow of gases. The flow of the media lifts a floating cone. This indicates the flow on a scale.
DOWNLOAD Specification sheet: robecco Strömungsmesser | Flow meter
Flow meter SM-M
❏ Brass housing |
❏ Corrosion-resistant materials |
❏ Easy installation |
❏ Easy measuring tube replacement |
❏ Vertical connection without valve |
❏ Not oxygen-cleaned |
❏ Vertical assembly |
❏ With alarm module |
❏ Optionally with regulator valve |
❏ Separate mounting brackets necessary |
Flow meter SM-VA
❏ Stainless steel housing |
❏ Corrosion-resistant materials |
❏ Easy installation |
❏ Easy measuring tube replacement |
❏ Vertical connection without valve |
❏ Not oxygen-cleaned |
❏ Vertical assembly |
❏ With alarm module |
❏ Optionally with regulator valve |
❏ Separate mounting brackets necessary |
Flow meter SM-K
❏ PTFE housing |
❏ Corrosion-resistant materials |
❏ Easy installation |
❏ Easy measuring tube replacement |
❏ Vertical connection without valve |
❏ Not oxygen-cleaned |
❏ Vertical assembly |
❏ Optionally with alarm module integrated (not retrofittable) |
❏ Optionally with regulator valve |
❏ Prepared for direct mounting |
Technical Data
Operating conditions Outflow against atmospheric pressure (20°C,1.01325 bar abs) |
Connection 2 x G 1/4″ female thread |
Temperature -15°C up to +120°C (media temp.) |
Pressure max.16 bar |
Installation length 210 mm (without connection accessories) |
Materials in contact with media Measuring tube: Borosilicate glass with enclosure Housing: brass |
Flow 0,2 up to 2l/min |
Technical Data
Operating conditions Outflow against atmospheric pressure (20°C,1.01325 bar abs) |
Connection 2 x G 1/4″ female thread |
Temperature -15 up to +120°C (media temp.) |
Pressure max.16 bar |
Installation length 210 mm (without connection accessories) |
Materials in contact with media Measuring tube: Borosilicate glass with enclosure Housing: stainless steel |
Flow 0,2 up to 2l/min |
Technical Data
Operating conditions Outflow against atmospheric pressure (20°C,1.01325 bar abs) |
Connection 2 x G 1/4″ female thread |
Temperature -20 up to +80°C |
Pressure 4 bar |
Installation length 205 mm (without connection accessories) |
Materials in contact with media Measuring tube: Borosilicate glass Housing: PTFE |
Flow 0,4-4l/min |
Alarm module | ||
---|---|---|
The flow is controlled by the alarm module. In case of falling below the setted min. flow, there is an alarm. | The flow is controlled by the alarm module. In case of falling below the setted min. flow, there is an alarm. | The flow is controlled by the alarm module. In case of falling below the setted min. flow, there is an alarm. |
Preessambled | Preessambled | optionally with alarm module |
Electronic evaluation unit SM-A-3 | ||
The electronic evaluation unit is used for signal conditioning. Electronic evaluation unit 24V / DC |
Order numbers
Flow meter SM-M-A-2 | R002030 |
Alarm module for flow meter SM-M | R000796 |
Mounting brackets for flow meter | R001399 |
Order numbers
Flow meter SM-VA-A-2 | R002031 |
Alarm module for flow meter SM-VA | R000796 |
Mounting brackets for flow meter | R001399 |
Order numbers
Flow meter SM-K-A-3 | R000134 |
Flow meter SM-K-3 | R000135 |
Electronic evaluation unit SM-A-3 | R000136 |