Sample gas compressor cooler KMK-2 / KMK-3.1 

In certain ambient conditions, compressor cooling systems are used for efficient gas cooling in the sample gas conditioning system. KMK sample gas coolers can be used for 1 to 2 gas paths.

Sample gas compressor cooler KMK-2

compressor cooling
1 or 2 heat exchangers or gas paths
Digital temperature display
Status relay as potential-free contact
Heat exchanger made of glass
Stainless steel housing
integrated condensate drain (peristaltic pump)

Technical Data

Dimensions over all
B 308 /H 312 /T 375 mm

Weight
17 kg
Connection of sample gas and condensate outlet
PVDF-hose tting DN 4/6
Protection class
IP 20
Supply voltage
220…240 VAC 50/60 Hz
Power input
190 VA
Switching capacity alarm output potential-free
max. 230V, 6A min., 5VA DC/5 mA
Heat exchanger glas WtG
Gas flow rate / max. gas temperature
max. 250 Nl/h / max. 140°C
Cooling capacity
160W

Sample gas compressor cooler KMK-3.1

compressor cooling
1 or 2 gas paths
Digital temperature display
Status relay as potential-free contact
Heat exchanger made of glass or stainless steel
Stainless steel housing
Sample gas cooler set incl. heat exchanger made of glas, condensate pump, fine filter, moisture detector (single or double)

Technical Data

Dimensions all about // 1 gas path
W 405 / H 295 / D 400 mm
Dimensions all about // 2 gas paths
W 490 / H 295 / D 428 mm
Weight
15 kg
Connection of sample gas and condensate outlet
PVDF-hose fitting DN 4/6
Protection class
IP 20
Supply voltage
115 V/ 230 V, 50 Hz
Power input
115V /60 Hz or 230V 50/60 Hz + 5%, 302 VA / 296 VA
Switching capacity alarm output potential-free
max. 250V, 2A, 50VA
Heat exchanger glas WtG / double-WtHeat exchanger stainless steel WtE /double-Wt
Gas flow rate
max. 280 l/h / max. 2 x 140 l/h
Gas flow rate
max. 530 l/h / max. 2 x 250 l/h
Cooling capacity
max. 450 kj/h / max. 230 kj/h
Cooling capacity
max. 450 kj/h / max. 450 kj/h

Order Numbers

Sample gas c.cooler KMK-2 WtG/1 gas path:R001657Sample gas c.cooler KMK-3.1 WtG/1 gas path 115V:R001890
Sample gas c.cooler KMK-2 WtG/2 gas path:R001659Sample gas c.cooler KMK-31 WtG/1 gas path 230V:R001891
Spare tube KMK-2, VE 5 piecesR000213Sample gas c.cooler KMK-3.1WtG/ 2 gas paths, 115V:R001892
Sample gas c.cooler KMK-3.1WtE/2 gas paths 230V:R001893
Equipment: