Sample line 

RSL-L / RSL-H 

Prefabricated sample lines with self-regulating heaters in di event performance classes.

With this exibility, a wide range of applications can be covered. The PTFE sampling tube is protected by an insulation and a polyamide 12 outer sheath. An application in a robust environment is possible.

RSL-L

– Individually customizable length of sample line, up to max. 100 m
– Self-regulating heating capacity: 17w/m; 23w/m; 31w/m
– Connection kit available extras
– Assembly:
C- profiles with clips and counter part (BK44mm)
min. bending radius: 100 mm
min. assembly temperature: 0o C
fastening distance horizontal: max. 1,0 m // – vertikal: max. 2,0 m

TECHNICAL DATA

Protective tube:
· Antistatic and UV resistant
· Very good cooling properties
· High, dynamic load-bearing capacity
· Halogen free and cadmium free
· Operating temperature range from -40°C to + 90°C //
(for short periods 150°C)
PTFE- tube:
· Anti adhesive, chemical resistant
· Serves the food quality (fully compliant with FDA requirements)
· Not flammable
· Operating temperature range from -70°C bis + 200°C
(for short periods 260°C)
· Tube available in diameters of 4 mm and 6 mm
· Compressive strength at 20°C: 4 mm- 12,0 bar// 6 mm- 8,5 bar
· Compressive strength at 100°C: 4 mm- 8,2 bar// 6 mm- 5,8 bar
Self-regulating heating tape:
· Max. allowable temperature: switched on 85°C
· Min. allowable temperature: -40°C (CENELEC -20°C
· Power supply: 220-277V AC / 110-120 V AC 50 Hz
· Temperature classification: up to 31W and/or 227V T4 (135°C)
· Max. reststance of the protective braiding: ≤ 18,2O Ohm
· Large range of approvals
· Adjusts to the heat capacity of the relevant work piece temperature · Heating tape available at capacities of 17W/m; 23W/m or 31W/m
· If required, the line lenght can be adjusted at site
· No overheating on overlapping

RSL-H

– Individually customizable length of sample line, up to max. 100 m
– Self-regulating heating capacity: 30W/m; 45W/m; 60W/m
– Connection kit available extras
– Assembly:
C- profiles with clips and counter part (BK44mm)
min. bending radius: 100 mm
min. assembly temperature: 0o C
fastening distance horizontal: max. 1,0 m // – vertikal: max. 2,0 m

TECHNICAL DATA

Protective tube:
· Antistatic and UV resistant
· Very good cooling properties
· High, dynamic load-bearing capacity
· Halogen free and cadmium free
· Operating temperature range from -40°C to + 90°C //
(for short periods 150°C)
PTFE- tube:
· Anti adhesive, chemical resistant
· Serves the food quality (fully compliant with FDA requirements)
· Not flammable
· Operating temperature range from -70°C to + 200°C
(for short periods 260°C)
· Tube available in diameters of 4 mm and 6 mm
· Compressive strength at 20°C: 4 mm- 12,0 bar// 6 mm- 8,5 bar
· Compressive strength at 100°C: 4 mm- 8,2 bar// 6 mm- 5,8 bar
Self-regulating heating tape:
·Max. allowable temperature: switched on 150°C
·Min. allowable temperature: -40°C
·Power supply: 220-277V AC; 50 Hz / 110V AC on request · Temperature classification: 200°C (T3)
·Max. reststance of the protective braiding: ≤ 18,2O Ohm
·Large range of approvals
·Adjusts to the heat capacity of the relevant work piece temperature Heating tape available at capacities of 30W/m; 45W/m or 60W/m
·If required, the line lenght can be adjusted at site
·No overheating on overlapping

ORDER NUMBERS Choose your sample line according to your applications

Extras:
Connenction kit R000998

Adjustable heating line incl. temperature sensor
With use of an electronic control unit, a exible heating of the sample line can be achieved. For this purpose, the line is fed to another produc- tion step and a PT100 sensor is integrated. The desired temperature can be adjusted on the electronic control unit.

Heating regulator

for 

With the use of a electronic control unit, the sample line temperature can be setted.

Technische Daten

Heating regulator

The desired temperature can be set manually

Compact design
2-line display ( nominal value and actual value)
Compatible with various temperature sensors
Multi-voltage input
4 – 20 mA output
Rated voltage
100- 240V AC
Switching power
1 Selctor 16A, 1 NC.switch 8A
Operating temperature
-5 … +55°C
Temperature
-200 … +800°C
Power consumption
4W
ATEX-certification
on request

ORDER NUMBER

  • Adjustable heating regulator
  • R 000525

Temperature sensor PT 100

Sensor is integrated in the sample line

Up to 180°C
3-wire
Flexible, with silicone connection cable
Rated voltage
MAX. 60 V
Measuring range
-50 … +180°C
Signal circuit
max. 1 mA AC/DC
Sensor diameter
6 mm
Measurement system
3-wire
ATEX- certification
on request

ORDER NUMBER

  • Temperature sensor PT 100:
  • R 000639

Conditions | AEB | Imprint Data ProtectionDownloadarea